Life Support BA case Communication System (Skovde coupling’s)

Categories: , Brand:
Article number: 3.80.3316

The Hytech Pommec BA Case is designed as a mobile life support system for high risk operations, such as inert entries. For more than 30 years, this system has proven its reliability within the life support industry, where it is deployed worldwide to ensure safe and controlled breathing air supply under extreme conditions.

Aantal
Add to Quote

Questions?

If you have any questions let us know

Product description

Life Support BA Box + Equipment Dynamic Communication

The Hytech-Pommec Life Support BA Box is a complete breathing air control and distribution system for inert entry applications. The system combines air supply control, breathing air distribution, monitoring, communication and supporting emergency equipment in a transportable setup. The main control unit is installed in an ABS transport case that separates into two sections: the A-Panel and B-Panel.

A-Panel air supply control

The A-Panel allows the operator to monitor supply pressures and select between LP and HP air sources. Under normal conditions, the system can operate from the LP supply. If the LP supply fails, the HP supplies automatically take over. Two high-flow regulators reduce HP air to approximately 15 bar, while an inline regulator reduces LP air to approximately 10 bar.

The panel includes multiple pressure gauges, emergency shut-off valves, HP and LP connection points and a built-in high-pressure alarm. If either HP supply to the regulators drops below 30 bar, the system activates a 120 dB acoustic alarm.

B-Panel breathing air distribution

The B-Panel receives air from the A-Panel and distributes it to a maximum of four breathing masks or helmets. Each worker connects through an umbilical with a double breathing air hose and communication cable. Individual flow meters and shut-off valves allow the operator to monitor and control each worker’s air supply.

The system uses double air connections for each worker, providing two supply lines throughout the breathing air system. A crossover valve links supply line 1 and 2, while isolation valves allow the individual lines to be controlled. The B-Panel also includes an acoustic alarm that activates if system pressure falls below 5 bar.

Monitoring, communication and life support lines

An inline monitoring panel can measure the O₂ percentage in two airline supplies and provides both high and low alarms. The monitoring equipment is installed in a stainless steel case.

Life support umbilicals connect the B-Panel to the workers’ breathing masks or helmets. The specified 25 m and 50 m versions each contain two 1/4″ breathing air lines and one four-wire communication cable, twisted together into one umbilical assembly. Other lengths are available on request.

The Life Support Communicator 2006F provides communication with up to six persons or rooms. It includes six microphone/speaker connections, a built-in speaker, a tender headset connection and a built-in 7 Ah battery for up to 20 hours of operation.

Additional system equipment

The complete specification also includes:

  • portable video equipment
  • APS life support helmet equipment
  • emergency air supply components
  • breathing masks
  • communication accessories
  • single-line air hoses
  • a safety harness.

Specifications

Specification Detail
Product Life Support BA Box + Equipment Dynamic Communication
BA Box article number T.98.00510
Transport case material ABS
Transport case construction Two separate sections: A-Panel and B-Panel
Transport case dimensions Approx. 640 × 480 × 380 mm
Transport case weight Approx. 49 kg
A-Panel HP connection points 4
Included HP connection hose length 4 m
A-Panel LP connection points 1
A-Panel supply pressure gauges 5 × Ø63 mm
Emergency shut-off valves 5
HP regulators 2 high-flow regulators
Reduced HP working pressure Approx. 15 bar
LP regulator 1 inline regulator
Reduced LP working pressure Approx. 10 bar
Reduced-pressure gauges 3 × Ø63 mm
A-Panel LP quick couplings 2
HP alarm activation Below 30 bar
HP alarm sound level 120 dB
B-Panel maximum users 4 breathing masks or hats
A/B connection hoses 2 × 40 m
B-Panel crossover valve 1
B-Panel isolation valves 2
B-Panel pressure gauges 2 × Ø63 mm
Double air connection quick couplings 4
Standard quick connector type Hytech Skovde
Optional quick connectors Euro or Hansen
Double flow meters 4
B-Panel low-pressure alarm activation Below 5 bar
Inline Monitoring BA Panel article number 3.20.908
O₂ monitoring 2 lines
O₂ alarm High and low alarm
Monitoring case Stainless steel
Inline reducer article number T.98.00752
Inline reducer tubing length 2 m
Inline reducer connections T-piece with DIN male and female connector
25 m umbilical article number U.99.00570
50 m umbilical article number U.99.00571
Umbilical breathing air lines 2 × FBL-04, 1/4″
Umbilical communication cable 1 × FCC-STP0502, 4-wire
Umbilical hose fittings Phosphor bronze swage fittings
Life Support Communicator 2006F
Communicator article number T.98.00903
Communication connections 6 microphone/speaker connections
Communication capacity Up to 6 persons or rooms
Communicator battery Built-in 7 Ah lead-acid battery
Battery operating time Up to 20 hours
Communicator dimensions 400 × 390 × 390 mm including cover
Communicator weight 15.2 kg including headset and charger
Protection class IP40
Operating temperature -25 to +50 °C
Power supply 11–15 VDC
Maximum supply voltage 15.5 VDC
Quiescent current Approx. 160 mA
Power consumption Max. approx. 20 W
Fuse 1.6 A slow
HEADSET/MIC headphone impedance 8–32 Ω
HEADSET/MIC microphone impedance 8–600 Ω
HEADSET 1–6 headphone/speaker impedance 8–32 Ω
HEADSET 1–6 microphone impedance 200–600 Ω
Portable video set article number T.98.00906
Video monitor 13-inch LCD
Video storage 128 GB solid-state drive
Video inputs 3
Video system battery 8800 mA Li-ion
Video control box size L320 × W220 × H120
Pan/tilt camera 50 mm
Pan/tilt camera window Sapphire glass
Pan/tilt camera lighting 6 dimmable high-light LEDs
Pan/tilt protection IP68
Pan/tilt cable reel 50 m
Fixed camera 29 mm
Fixed camera lighting 15 dimmable high-light LEDs
Fixed camera cable reel 50 m
Fixed camera classification CNEX Zone 2
Camera clamp range 0–140 mm
Camera spreader range 170–350 mm
Camera adjustment 360° via ball joint
Anti-Panic Security Helmet article number T.98.01491
Helmet shell Carbon-fibre composite
Helmet air supply Two independent air supply lines
Helmet regulators Two independent regulators
Helmet visor Impact-proof polycarbonate
Helmet communication Full-duplex
Helmet marking CE marked
Y Manifold Airtech Block article number 3.80.4687
Umbilical connections on Y manifold 2 independent connections
Bail-out supply connection 1
Third air supply connection 1
Helmet regulator test supply 120–125 PSI / 8.5 bar
Bail-out cylinder article number 5.10.219
Bail-out cylinder capacity 1 litre
Bail-out cylinder pressure 200 bar
Emergency escape system article number T.98.00864
Emergency cylinder capacity 20 litre
Emergency cylinder pressure 200 bar
Emergency system pressure gauges 2 × Ø63 mm
Emergency manifold outlets 4 quick couplings
30 m single-line article number U.99.00067
30 m single-line hose FBL04, 1/4″, 30 m
Interspiro breathing mask article number T.99.01282
Headset article number T.98.00004
Microphone unit article number 3.80.1289
Communication adaptor article number T.98.00001
2-way harness air block article number 5.10.218
Harness flexible hoses 400 mm and 900 mm
Interspiro LP air line article number U.99.00284
Interspiro LP air line length 1 m
Strain relief belt article number T.98.00642
50 m single-line article number U.99.00424
50 m single-line hose FBL04, 1/4″, 50 m
Safety harness article number T.99.02358
Safety harness Central lifting point

 

Features

  • Portable ABS transport case with separate A-Panel and B-Panel
  • LP and HP breathing air supply control
  • Automatic HP takeover if LP air supply fails
  • Built-in high-pressure alarm
  • Air distribution for up to four workers
  • Double air supply arrangement for each worker
  • Individual flow meters and shut-off valves
  • Low-pressure acoustic alarm on B-Panel
  • Dynamic communication equipment for up to six persons or rooms
  • Inline O₂ monitoring for two air lines with high and low alarms
  • Compatible with 25 m and 50 m life support umbilicals
  • Emergency air supply equipment available within the described system
  • Communication and portable video equipment included in the system specification